Troubleshooting
Find your symptom, get the fix. Almost everything here is something you can resolve yourself or with a one-line ask to an admin — no support ticket required. Organised by what you actually see on screen.
Scan the headings for the thing that's happening to you, then open it. Each one tells you the likely cause and the exact next step. If a fix says "ask an admin," the precise sentence to send them is included.
Can't get in
Login problems
The login fields are greyed out, with a "not configured" banner
This is an admin/install issue, not yours: the platform's first-run config hasn't been written. You can't log in until it is. Send the admin to first-day setup — they either populate the required values in the environment file and bring the stack up again with make up (a plain restart does not re-read it), or use the wrench icon on the login page to finish setup. Then reload. On the config page itself, repeated wrong passwords answer Too many failed login attempts; try again in N seconds and keep Sign in disabled for that wait; a single wrong password still reads Invalid config password.
Sign-in says "Too many sign-in attempts"
HERD counts every sign-in attempt, right or wrong, against the network address it comes from, and this address has made too many in a short time. It does not mean your account is locked or that your password is wrong. Wait the number of seconds the message gives, then sign in again. Everyone behind one office router or VPN shares the same allowance, so if it keeps happening to a whole site, tell an admin; they can raise the limit.
Registering says local registration is disabled
Your company runs HERD against its corporate directory (LDAP/AD), so self-registration is off: the sign-in card shows no Register link, and the Register page, opened by its address, answers Local registration is disabled; this deployment uses LDAP authentication. when submitted. You don't need it: just sign in with your directory username and password; your account is created automatically on first login.
I was logged in, now everything errors / I get logged out
Your session likely ended. The 30-minute sign-in token refreshes on its own, and all your open HERD tabs share one session, so a refresh in one tab does not sign out the others; once the refresh itself is refused (for example after a week), you are sent to the sign-in page. Sign in again; signing in with the same account returns you to the page you were on. If it keeps happening right after you sign in, tell an admin.
The browser warns about the certificate
Expected on an install that serves HERD with the self-signed certificate make certs generates, or at an address the certificate does not name. Nothing on your side is wrong and there is nothing for you to change. For the self-signed certificate, an admin trusts server-chain.crt on each client, or installs a CA-signed chain in its place (FRESH_SETUP.md, step 3); until then the warning stays. For an address the certificate does not name, trusting it is not enough: an admin adds the address (in HERD_GATEWAY_BIND, or as a CERT_SANS entry on the same command), runs make certs CERT_FORCE=1, and recreates Traefik; clients then trust the new certificate.
Everything's empty
Inventory / palette shows nothing
Inventory says "No devices found"most common
Your user group hasn't been granted visibility to any device group yet. This is the number-one day-one confusion and it's a one-line admin fix.
Send your admin exactly this: "Can you add my user group to the device group(s) for the gear I need?" Then reload. (Admins: setup step 5.)
Less commonly: every device you can see is currently reserved and the palette's Show reserved resources toggle is off — flip it on.
The Inventory list has devices but the topology palette is empty
By design: the palette only shows DUTs (Management-type devices). If everything you can see is infrastructure switches, the palette stays empty — switches are wired in automatically by the routing system, not dragged by hand.
Reservation won't go through
Errors when booking
"Time conflict: devices already reserved"
An exclusive device you picked is already held during your window. Three options: pick a different window (the calendar shows the gaps), cancel the conflicting booking if it's yours, or swap in a different device. A device someone is mid-booking also counts as a conflict until they finish.
"The following devices are not available"
A device's status doesn't allow it. Exclusive devices must be AVAILABLE; if one shows RESERVED it's held elsewhere. OFFLINE or MAINTENANCE means an admin took it down on purpose — ask them if it shouldn't be.
"All devices must share the same topology type"
You mixed PHYSICAL and CLOUD devices in one booking. Split it into two reservations, one per type.
My reservation shows FAILED
No devices were actually reserved — provisioning couldn't complete, and the row is kept only for audit. Just create a new reservation for the same devices and window; it usually succeeds on the retry once the backend is healthy. If it fails repeatedly, that's an admin-side service issue (an inventory or internal-token problem) — flag it.
Stuck in PENDING past its start time
The activation task runs about once a minute, so give it up to 60 seconds of drift. If it's been much longer than that, the task may have stalled — tell an admin to restart the reservations service.
A red topology edge
The edge won't go green
Red + "no path"
No physical route exists between the two DUTs through known switches. Either they're genuinely in isolated fabrics, or the switches/cabling between them aren't recorded in inventory. Ask an admin to verify the cabling (or do it yourself via Cabling things up). For deliberate cross-site links, an admin adds a virtual tunnel device cabled into both fabrics.
Red + "uncabled port"
The specific port you chose has no physical cable recorded. Delete that line and redraw it against a different port in the wiring dialog (a cabled port is tagged CABLED; an uncabled one is tagged no cable, both informational, but only a cabled port will resolve a real path), or ask an admin to record that cable. To change just one line, click its layer pill on the canvas to expand its own delete control; or, if it's bundled with other connections between the same pair, click the bundle's count badge to find and delete that one connection.
"Can't drop the device here"
You're trying to mix a PHYSICAL device with a CLOUD one. They can't share a topology — start a separate one for the other type.
A route refused with "l3_vrf_unsupported"
The route names a virtual router, and the switch's driver does not declare supports_vrf, so HERD refused the route instead of installing it in the default routing table. Nothing was sent to the device, and the route stays in the Wiring tab as failed until the intent or the driver changes. Two fixes: remove the virtual router from the route in the topology editor's Routing panel, or have an admin upload a driver that supports virtual routers (the shipped frr_l3 package does). See routing intent.
Retry reported rows as "already retrying"
HERD's own background retry was working on those rows when you pressed Retry failed, so your retry left them alone rather than driving the same connection twice. Nothing is wrong and nothing is lost: check the Wiring tab again in a minute for the background channel's result.
AI weirdness
AI generation problems
There's no "Use AI" button
Two causes now: the provider is not configured, or it is configured but cannot be constructed (a bad base URL, an unreadable CA file, a key of the wrong shape). Nothing you can do as a user; ask your admin. Admins can tell the two apart with GET /api/ai/status: a broken-but-configured provider reports enabled: false, degraded: true, reason: <error class name>. The detail message never leaves the service, so check the ai-orchestrator logs for it. The status is cached for 30 seconds, so a fix can take that long to show.
"Inventory shifted during generation"
A device the AI wanted became unavailable between proposing and committing. Just regenerate — it'll plan against the current inventory.
My device configs came back "admin required"
Pushing configs to devices is admin-only. Your topology and reservation were still created fine — only the config step failed. Either untick "Apply device configs" at commit, or have an admin apply them separately.
Generate failed with a toast listing role pairs
The generator could not find devices that can be wired for every proposed link. The toast shows a sentence, for example "The lab has no cabled path for 1 proposed connection; the topology cannot be built from the devices currently available.", then one "source role to target role" line per pair. Nothing is saved. The cause is that no cable is recorded between available devices of those two kinds. Either an admin records the cabling (Administration, Connections; see Cabling things up), or you ask again with different devices. The generator already re-asks the model up to two times (AI_GENERATE_MAX_REPAIRS, default 2) before this appears.
"Commit failed: cannot wire this topology"
After Accept, the commit checks the saved topology against cabling before it creates the reservation. The toast lists one line per problem link, "<source role> to <target role>: <reason>", with the reason in plain words: "no cable path", "device not found", "cannot connect two elements directly", or "element has no available port". The just-created topology is deleted and no reservation exists. Fix the cabling, or reject and regenerate. If cabling itself cannot answer, the commit fails with an ordinary error toast instead.
There's no "AI Assistant" tab on my reservation
Two reasons it hides: AI isn't configured on this deployment (same switch as the Use AI button), or you don't own that reservation — the assistant only runs against reservations that are yours.
The assistant timed out or says it can't see a device
Timed out: a heavy question fanned out into too many lookups — ask something narrower or split it in two. If the assistant had already run tools before the timeout, the turn is kept and ends with "The steps above ran, but the assistant could not finish this reply. Review the results before continuing."; read the tool panel before asking again, since something may already have changed. "Can't see that device": it's bounded by your visibility on purpose; if you can't see the device in inventory, neither can the assistant. Same permissions fix as an empty inventory.
Generate refuses my reference files: too many, too big, or "Unsupported file type"
The reference files you attach to Use AI are checked before the AI is asked anything. A refused file fails the whole request: nothing is extracted and no proposal is made, so remove or replace the file and generate again. The messages, and what they mean at the default limits:
Too many files: limit is 5, got N. Attach at most 5 files.File '<name>' exceeds limit of 5242880 bytes. Each file may be at most 5 MB. Trim it, or attach only the part that matters.Unsupported file type '<ext>' for <name>. Accepted: .pdf, .txt, .md, .json, .xml, .tgz, .tar.gz. Any other extension is refused. Rename a plain-text log or config to.txt, or put it inside a.tgz(a tgz reads its.txt,.md,.json,.xml,.log,.cfg,.conf,.yaml, and.ymlmembers).Failed to parse PDF (<ExceptionClass>). The PDF could not be read; the class name is all HERD shows. Re-export it, or paste the text into the prompt.
These are not refusals: all files together contribute at most 80,000 characters of text, and a file cut at that budget is marked truncated. Your admin can change the file count, per-file size, and text budget (UPLOAD_MAX_FILES, UPLOAD_MAX_FILE_BYTES, UPLOAD_MAX_EXTRACTED_CHARS); the numbers above are the defaults. A tgz has further limits, in the next entry.
Generate refuses my .tgz: "Failed to read tgz archive" or "nothing was extracted"
A .tgz or .tar.gz (a tech support bundle, for example) is read with fixed safety limits that no setting changes. Any refusal fails the whole request: nothing is extracted and no proposal is made. The message says which limit you hit:
Failed to read tgz archive (ReadError). The file is not a gzip archive, the compressed stream is cut off or corrupt, or the first tar header is bad. Re-create the archive and check it withtar -tzf.Failed to read tgz archive (RecursionError). Several hundred pax or long-name headers in a row, more than the reader can follow. Re-create the archive without that run.The tgz archive has more than 10000 entries; nothing was extracted. At most 10,000 members. Archive a smaller directory.The tgz archive extends past 104857600 bytes uncompressed; nothing was extracted. At most 100 MiB once decompressed, even though the file itself is under 5 MB. Leave out large binaries and core files.The tgz archive has more than 65536 bytes of pax extended headers and GNU long names in front of one member; nothing was extracted. At most 64 KiB of long-name and extended header data together in front of any one member (an honest archive uses a few KB).The tgz archive has more than 4096 bytes of pax global headers; nothing was extracted. At most 4 KiB of pax global headers in the archive (the onegit archivewrites is 52 bytes).The tgz archive has a sparse member, which is not supported; nothing was extracted. A sparse file, for example fromtar --sparse, cannot be read. Re-create the archive without--sparse.The tgz archive has a tar header record over 1048576 bytes (a pax extended header or GNU long name); nothing was extracted. A single header record over 1 MiB. The 64 KiB limit above refuses such a header first, so you should not meet this one.
Health & config
Polling & config pushes
A device shows UNREACHABLE but I can reach it
The health poll logs in exactly the way a real run would. If it can't authenticate (wrong IP / login / password in the device fields), it reports UNREACHABLE even though you can reach the box by other means. Fix the field data. Note also that after repeated failures the poll interval stretches out, so the badge can lag a recovery by a cycle.
No health badge at all on a device
That device isn't opted into polling. Set a poll interval (minimum 30s) on the device or its template — see health monitoring. No interval, no badge.
"Dry-run not supported" when scheduling a config apply
The device's driver hasn't declared dry-run support, so HERD refuses to simulate against it rather than guess. Either apply for real (carefully), or have the driver author add dry-run support. Restoring an old config version is also blocked while an active or pending reservation references the topology.
Admin / driver issues
Setting things up
Driver upload fails with 422 or 409
422 = the package was refused and nothing was stored; the message says why. Usually it is the wrong file type or too big: use a .zip or .tar.gz under 10 MB. A package is also refused when its driver_metadata.json is larger than 1 MiB, or when a .tar.gz holds a tar header record (a pax extended header or GNU long name) over 1 MiB. 409 = the driver name is already taken; names are unique, pick another.
Can't delete a driver
A template still points at it — drivers are reference-counted. Remove or repoint the template first, then delete the driver.
A service exits at startup naming AUTH_SECRET_KEY or AUTH_ALGORITHM
The key is unset, blank, still the .env.example placeholder, or not usable as an HMAC secret, or AUTH_ALGORITHM is something other than HS256, HS384, or HS512; since 0.7.0 every service that checks access tokens checks both as it starts and stops with a message naming the variable. Put a random value (openssl rand -hex 32) in .env, or in the config UI if a configuration was saved there, since a saved configuration outranks .env; then make up. A value under 32 bytes starts, with a warning in the log.
make up refuses to start, or https://localhost is refused
Two different causes. First, another compose project holds host port 80 or 443; the message names it. Use that stack as it is, or, when it is this checkout's seeded gate stack, run make gate-down (which purges the gate stack's database) and then make up. Second, HERD_GATEWAY_BIND in .env publishes the gateway on one address only, so localhost and every other interface are refused by design; the address to browse is the one make gateway-url prints.
Traefik fails to restart with a not a directory error after an upgrade
A Traefik container created before 0.7.0 still mounts infra/traefik/traefik.yml, which 0.7.0 deleted, so a restart fails on the mount and leaves a root-owned directory at that path. After pulling, recreate Traefik with make up or docker compose up -d before anything restarts it. If the error has already happened, remove the directory with sudo rmdir infra/traefik/traefik.yml, then recreate.
Can't delete a device
A reservation still holds it. Deleting a device that any non-terminal reservation holds is refused with device_in_use, and the error names the reservation ids. This includes a switch or router that no one booked but that carries a live reservation's wiring as a transit hop; the error then lists those reservations as transit holders. Release or complete those reservations first, then delete. If you delete right after cancelling, the device can stay blocked for a few seconds while the wiring is released. There is no force option.
A device that is still cabled is refused too, with device_cabled and the number of connections that name it. The device page shows the count and a link to the Connections page. Delete those connections first (a device with no reservation can then be deleted straight away); there is no force option here either. If a reservation also holds the device, the reservation message comes first.
"Could not verify device visibility; connections were not returned"
The connections list filters what a non-admin sees by device visibility, and that lookup could not be answered, so the list failed closed rather than show connections you may not be allowed to see. Retry the request. If it keeps happening, the visibility lookup itself (the inventory service) is unhealthy; that one is for ops.
A bulk import rejected some rows
Read the per-row reason in the report — usually a reference that didn't resolve ("template not found by name"). Imports resolve references by name, so import templates before devices and devices before topologies. A reject never aborts the batch; fix the named rows and re-run. Always dry-run first to preview the whole thing.
A user reports the bell never ticks up
Check in their Settings → Notifications that the in-app channel is on and the relevant event type is still checked. Reservation events go to the reservation owner; health events go to admins and anyone with an active reservation on the device. If they expect email or chat, those are separate opt-in channels — off until switched on. Deeper failures are NATS/consumer issues for ops.
Genuinely stuck?
When it really isn't you
If you've matched a symptom above and the fix didn't take, it's likely a backend/ops problem rather than something in the UI. Before escalating, gather the four things that make it a five-minute fix instead of a back-and-forth:
- The exact error message (and the HTTP status if it's an API error).
- Your role (user / admin / superadmin).
- What you were trying to do when it happened.
- Roughly when it happened, so logs can be matched.
Every backend service exposes live API docs at https://<your-host>/api/<service>/docs (admin login required for most endpoints) — handy for confirming whether a problem is the UI or the service behind it.